Start here

How to shut down and restart your solar system safely

You may need to switch your solar off for a roof leak, a storm, a fault light or a technician's request. Doing it in the right order protects the equipment and you.

4 min readUpdated November 2026From the Energy Solution Providers service team

The short answer

Off: inverter switch first, then the AC disconnect, then the solar breaker. On: the same three in reverse. After switching back on, the inverter waits about five minutes before it starts producing.

When you might need to

  • A technician or the utility asks you to.
  • A roof leak, a storm-damaged panel, or water near any of the equipment.
  • A burning smell, a scorched-looking breaker, or an inverter that is unusually loud or hot.
  • Work on the roof, the electrical panel or the meter.

Turning the system off does not make the roof wiring safe. Panels produce voltage whenever light hits them. Shutting down stops power flowing into your home, but panel wiring and connectors on the roof can still be live. Never touch, unplug or cut solar wiring.

Shutting down: the safe order

  1. Turn off the inverterOn a string inverter (SolarEdge, SMA, Fronius and similar), turn its main switch to OFF or 0. On SolarEdge, wait until the screen or app shows the DC voltage has dropped, which takes about five minutes. Microinverter systems (Enphase, APsystems) have no switch at the inverter: skip to step 2.
  2. Turn off the AC disconnectPull the handle on the gray disconnect box near the meter to OFF.
  3. Turn off the solar breakerIn your main electrical panel, switch the breaker labelled solar, PV or inverter to OFF.
  4. If you have a battery, follow its steps tooBatteries such as Tesla Powerwall, Enphase IQ Battery and Generac PWRcell have their own switch or breaker. Your installer's manual shows the order. If you do not have it, call us before switching a battery off.
  5. Rapid shutdown, if you have oneNewer systems have a rapid shutdown switch near the meter. In an emergency it is the one switch that shuts the system down and lowers the voltage on the roof wiring. Fire crews use it too.

Starting back up

  1. Solar breaker onSwitch the solar breaker in the main panel back to ON.
  2. AC disconnect onPush the disconnect handle back to ON.
  3. Inverter onTurn the inverter switch back to ON or 1. On SolarEdge inverters with a P/1/0 switch, use 1. The P position is for setup and pairing, so leave it alone unless a technician asks.
  4. Wait about five minutesGrid-tied inverters must see steady grid power for about five minutes before they start producing. A blinking light during this time is normal.
  5. Check it is producingLook for the normal green light, then check the app in 15 to 30 minutes. If it shows a fault again, write down the message and leave it off.

Brand notes

SystemWhere the switch isWhat normal looks like after a restart
SolarEdgeP/1/0 or ON/OFF switch on the inverter, plus a DC safety switch on many modelsGreen light blinks, then stays on once producing. Light guide.
EnphaseNo switch at the inverters: use the breaker and AC disconnectGateway production light turns green once the microinverters start. Light guide.
SMA Sunny BoyDC switch (rotary) on or under the inverterGreen light flashes while it checks the grid, then stays on. Light guide.
FroniusDC switch on the side or front of the inverterScreen counts through its startup checks, then shows power. Code guide.

Tip. If a breaker or switch is hard to move, feels hot, or the label is missing, do not force it. Call us and we will walk you through it on the phone.

Questions people ask

Does switching off make the panels safe to touch?

No. Panels make electricity whenever light hits them, and the wiring on the roof can still be live. Shutting down stops the system feeding your home. It does not make the roof wiring safe.

Will a restart clear an error?

Sometimes. A restart clears faults that were caused by a short grid problem. If the same error comes back, the restart is only hiding a fault that needs finding, so leave it off and call us.

How long can I leave the system off?

As long as you need. Nothing is harmed by leaving it off, you just do not make power for that time.

This guide is general advice for Arizona homeowners. Your equipment's manual has the final word, and anything inside the inverter, on the roof or in the electrical panel is a job for a licensed contractor.

Accredited, award-winning and Arizona licensed

AriSEIA member — Arizona Solar Energy Industries AssociationHomeAdvisor Top RatedHomeAdvisor Elite Service awardBetter Business Bureau accredited business, A+ ratingSolarReviews — read our customer reviewsAngi Super Service Award 2023Angi Super Service Award 2022
Call us Text Get a free quote

Type at least two letters.