Lights and error codes

SMA Sunny Boy lights and error messages, explained

SMA Sunny Boy string inverters are on thousands of Arizona roofs. Newer models talk through three lights and the Sunny Portal app. Older ones have a small screen. Here is how to read both.

5 min readUpdated November 2026From the Energy Solution Providers service team

The short answer

Green on means producing. Green flashing means waiting for enough sun. Red means an error: the event shows in Sunny Portal or on the screen. Grid messages often clear by themselves.

Which Sunny Boy do you have?

  • Newer models (Sunny Boy US-40 and US-41, roughly 2017 on) have three lights on the front and no screen. You see details in the Sunny Portal app, or by connecting to the inverter with a phone.
  • TL-US models (roughly 2011 to 2017) have a small screen and three lights.
  • Older models such as the SB 5000US, 6000US and 7000US have a text screen. Many of these are now well past their warranty.

What the lights mean

  • Green, onFeeding power in. All is well.
  • Green, flashingWaiting for conditions to feed in: not enough sun yet, or the grid checks after a restart. Normal at dawn, dusk and for a few minutes after switching on.
  • Green, offNot feeding in. Normal at night. During a sunny day, check the solar breaker and DC switch.
  • Red, onAn error or event has stopped the inverter. The message shows in Sunny Portal or on the screen.
  • Blue, onConnected to your network. A slow flash means it is trying to connect.

Tip. If the green light flashes all day in full sun, the inverter is not seeing enough voltage from the panels. That points to a DC switch that is off, or a wiring fault between the roof and the inverter.

Common messages and what they point to

MessageWhat it usually meansWhat to do
Riso, insulation failure, or earth faultThe panel wiring is leaking to ground: a damaged cable, water in a connector, or wiring chewed by birds or rodentsOften shows on damp mornings first. It needs finding: book a visit.
Vac-Bfr, Vac-Srr, or grid voltageThe grid voltage is outside the allowed rangeUsually clears itself. If it happens most sunny afternoons, we can measure the voltage at your home.
Fac-Bfr, Fac-Srr, or grid frequencyThe grid frequency is outside the allowed range, often during an outage or right after oneWait. If it does not clear once the power is steady, call.
Grid fault, or no gridThe inverter cannot see the gridCheck the solar breaker and AC disconnect.
Arc fault detectedA spark was detected in the DC wiring, usually a loose or damaged connectorThe inverter stays off until reset. Do not keep resetting it: book a visit so we can find the cause.
DeratingThe inverter is hot and has reduced its output to protect itselfCommon in Arizona summers, especially on west walls. A shade cover often helps. See solar in the heat.
Fan fault, or self-test failedAn internal part has failedA service call. On older units, compare the repair with a replacement.

The Secure Power Supply outlet

Many TL-US and US-40/41 Sunny Boys have a feature called Secure Power Supply. If your installer fitted the special outlet and switch for it, you can get some power from the panels during a daytime outage, even without a battery.

  • It only works while the sun is shining, and output rises and falls with clouds.
  • It gives up to about 2,000 watts: enough for a phone charger, a fridge in short bursts, a fan or a laptop, not the air conditioning.
  • To use it, turn the Secure Power Supply switch on during the outage, and plug into its outlet. The rest of the house stays off, as it must.

Not sure whether you have one? Look for a separate outlet with a label near the inverter, usually with its own switch. See why solar turns off in a power outage.

Repair or replace?

A Sunny Boy that is 12 or more years old and has an internal fault is usually better replaced than repaired. A new inverter matched to your panels brings a fresh warranty and better monitoring. Replacements start from about $2,000 installed, depending on size. We will tell you honestly which makes more sense for yours.

Questions people ask

Is it worth repairing an old Sunny Boy?

It depends on the fault and the age. Many older Sunny Boys came with 10-year warranties, so a lot of them are now past it. When one fails after 12 or more years, a replacement is usually better value than a repair.

This guide is general advice for Arizona homeowners. Your equipment's manual has the final word, and anything inside the inverter, on the roof or in the electrical panel is a job for a licensed contractor.

Accredited, award-winning and Arizona licensed

AriSEIA member — Arizona Solar Energy Industries AssociationHomeAdvisor Top RatedHomeAdvisor Elite Service awardBetter Business Bureau accredited business, A+ ratingSolarReviews — read our customer reviewsAngi Super Service Award 2023Angi Super Service Award 2022
Call us Text Get a free quote