The short answer
Green on means producing. Green blinking means waiting (night, or switched off). Red means a fault: note the message in the app. Blue is the link to SolarEdge monitoring.
Which SolarEdge do you have?
SolarEdge has made two main styles of home inverter. Look at the front:
- No screen, three small lights (green, blue and red) and a switch marked P, 1 and 0. These are the newer SetApp models, including most HD-Wave inverters from around 2019 on. You read them in the mySolarEdge app.
- A small text screen with an ON/OFF switch. These are the older models, common on Arizona homes installed before about 2019. They show their status as lines of text.
Either way, every panel has a power optimizer behind it, so the app can show you each panel on its own. That makes it much easier to tell an inverter problem from a panel problem.
What the three lights mean
- Green, onThe inverter is producing power. This is what you want to see on a sunny day.
- Green, blinkingStandby: the inverter is on but not producing. Normal at night, early morning and late evening, for a few minutes after a restart, or when the switch is at 0.
- Blue, onConnected to SolarEdge monitoring, so the app is getting data.
- Blue, blinking or off for a long timeIt is not reaching the SolarEdge servers. The system may still be producing fine. Usually an internet or Wi-Fi change: see reconnecting your monitoring.
- Red, onThe inverter has logged a fault. Open the mySolarEdge app to see the message, take a screenshot, and check the list below.
- Lights cycling togetherUsually a firmware update or startup. Leave it alone for half an hour before doing anything.
Reading an older SolarEdge screen
On older models, tap the button under the screen (or the light switch on some units) to step through the status pages. The lines that matter most:
| Line | What it means | What to look for |
|---|---|---|
| Vac | The grid voltage the inverter sees | Around 240 V on most Arizona homes. Much higher or lower can cause grid errors. |
| Vdc | The voltage coming in from the panels | When producing, usually about 380 V on most home models. When off, about 1 V for each optimizer (a safety mode). |
| Pac | The power going out to your home right now | Watts. Zero during the day means it is not producing. |
| P_OK: x of y | How many optimizers have reported in | x should match y, the number of panels. A lower x points to an optimizer or its wiring. |
| S_OK | Connected to the SolarEdge server | If it is missing, the app is not updating. |
| ON/OFF | The switch position | Should read ON. OFF means the switch is off or it is waiting to start. |
Tip. With the inverter switched off, Vdc reading about the same number as your panel count (for example 22 V on a 22-panel system) means every optimizer is in its safety mode and wired through. That is a healthy sign.
Common error messages and what they point to
SolarEdge shows a message and a code. The code numbers vary by model and firmware, so go by the wording.
| Message | What it usually means | What to do |
|---|---|---|
| Isolation fault, or ground fault | Electricity is leaking from the panel wiring to the frame or ground: often a damaged cable, a wet connector, or a chewed wire | If it shows only on damp mornings and clears by midday, it is still a real fault that tends to get worse. Book a visit. |
| AC voltage too high, or grid voltage out of range | The grid voltage at your home is outside the allowed range. Often a sunny afternoon with many homes exporting, or long wiring to the meter. | It clears itself when the voltage settles. If it happens most days, we measure it and may need the utility involved. |
| Grid frequency, or no grid | The inverter cannot see a stable grid: an outage, a tripped breaker, or the AC disconnect off | Check the solar breaker and disconnect. If they are on and the house has power, call. |
| Arc fault detected | The inverter heard the electrical signature of a spark in the DC wiring, usually a loose or damaged connector | It will stay off until restarted. Do not keep restarting it. Book a visit so we can find the connector. |
| Optimizers not reporting, or low P_OK | One or more optimizers have failed or lost connection | Check the panel view in the app. A failed optimizer is usually a warranty part. |
| Temperature, or derating | The inverter is too hot and has reduced its output | Common on west walls in summer. See solar in the heat. |
Use the panel view in the app
In the mySolarEdge app, the layout view shows the energy from each panel. At midday on a clear day, panels on the same roof face should read close to each other.
- One panel at zero: that panel's optimizer or connectors. The rest of the system is fine.
- A whole row or string at zero: a wiring fault between the panels and the inverter, or a string fuse.
- Everything at zero: the inverter, a breaker, or the grid.
- One panel a little lower: often a shadow, a bird dropping, or dirt. Check at a different time of day.
Leave the inside of the inverter alone. It holds high DC voltage even when switched off. Restarting the inverter is fine; opening the cover is not.
Questions people ask
One panel shows zero in the app. Is that the inverter?
Usually not. One panel at zero points to that panel's optimizer or its connectors. The inverter is fine if the rest of the panels are producing.
Is my SolarEdge inverter still under warranty?
SolarEdge inverters were usually sold with a 12-year warranty, which some owners extended to 20 or 25 years, and optimizers with 25 years. Give us the serial number and we can check.
This guide is general advice for Arizona homeowners. Your equipment's manual has the final word, and anything inside the inverter, on the roof or in the electrical panel is a job for a licensed contractor.