The short answer
Open the EMA app and look for a group of two or four panels at zero: that is one APsystems microinverter. If the whole system shows no data, check the ECU box and your internet first.
What you may notice
- A group of two or four panels producing nothing in the EMA app
- The ECU showing offline, or no data in the app
- Production down on the same month last year
- An older YC500 or YC1000 system with units failing
Usual causes
- A failed microinverterOne APsystems unit usually serves two panels (YC500, DS3) or four panels (QS1, YC1000), so one failure takes out a group.
- The ECU is offlineThe ECU box reports to the EMA app. A router change or a failed ECU stops the reporting.
- A tripped breaker or wiring faultA tripped branch or damaged trunk cable takes out a row of units.
- Discontinued older unitsOlder YC500 and YC1000 units are no longer made. Replacements need matching to the system.
What you can safely check
- Look at the EMA app's module viewNote which panels are at zero, and whether they are in pairs or groups of four.
- Check the ECUIs it powered, and are its lights normal? If it shows no network, see reconnect your monitoring.
- Check the solar breakerIn the main panel and any sub-panel.
- Compare with last yearUse our production checker if you are not sure what is normal.
APsystems models we see
| Model | Panels per unit | Notes |
|---|---|---|
| YC500 | 2 | Older and discontinued. Replaced with a current model. |
| YC1000 | 4 | Three-phase, mostly on commercial systems. Discontinued. |
| QS1 | 4 | Common on homes from the late 2010s. |
| DS3 | 2 | The current model on most new home systems. |
Burning smell, smoke or sparks? If it is safe, turn off the solar breaker and the AC disconnect and keep clear. If there is fire, call 911. See how to shut down safely.
What we do
We test panel by panel to find the weak spot, and clean the array if dirt is the problem.
Because one APsystems unit often serves two or four panels, a single failure takes out more of the array than with one microinverter per panel. We replace failed units under warranty where they are covered, and match newer models to older systems where the old ones are discontinued.
- You call or book onlineTell us what the system is doing. Photos of the inverter screen or app help us bring the right parts.
- We find the causeA technician tests the system from the panels to the meter, so we fix the actual fault, not just the symptom.
- You get the price firstWe explain what failed and what it costs to fix before any work starts. Covered parts go through the manufacturer's warranty.
- We fix it and test itMost repairs are done in one visit. We confirm the system is producing and the monitoring is reporting before we leave.
What it costs
From $150 to find the cause, then a clear price for the fix. Service calls start from $150, and repairs can be financed.
See all repair prices →Questions people ask
The EMA app shows some panels at zero. What does that mean?
Usually one microinverter has failed or lost its connection. We confirm it on the roof and replace it.
Can a new APsystems unit replace a discontinued one?
Usually, yes. Newer models work with most older systems, with the ECU updated to see them.
General advice for Arizona homeowners. Your equipment's manual has the final word, and anything inside the inverter, on the roof or in the electrical panel is a job for a licensed contractor.